Diverse Ferrite Meter

  • Rp. 0

Deskripsi : The Diverse Ferrite meter MF300Fe+ measures the Ferrite number (FN) of austenitic and duplex stainless steel weld material. It has a probe that is sensitive to ferrite content in a 10 mm area to a depth of approximately 1 mm. The instrument is calibrated using the secondary weld standards validated by National Institute of Standards and Technology (NIST) in the USA. All 16 standards are used in the calibration giving an instrument with a measurement range from 0 to 115 FN. Transfer standards are supplied with the instrument allowing performance to be verified at any time. A variety of measurement modes are supported to ensure that good repeatable measurements can be made. Measure Ferrite Content of Austenitic & Measure Ferrite Content of Austenitic & Duplex Steel Features - Non-destructive test of the ferrite content in a Non-destructive test of the ferrite content in a Non-destructive test of the ferrite content in a range of 0.1 to 115 FN equivalent to 0.1 to 80.5% range of 0.1 to 115 FN equivalent to 0.1 to 80.5% Fe in austenitic and duplex steel. - Robust and portable - Standard or peak measurement of Ferrite Number - Estimate of ferrite percentage (70% of FN) - Automatic zero on demand - Supplied with 5 transfer standards allowing Supplied with 5 transfer standards allowing veracity of instrument to be checked - Storage of 52 measurements, downloaded to PC with RS232/USB (option) - Use with high temperature samples (air-cooled probe option) - Simple measurement with small sample area. - Units selectable between WRC-FN and %Fe. Units selectable between WRC-FN and %Fe. - Calibration to weld standards validated by NIST to weld standards validated by NIST - Supplied in carry case MF300F+: Performance Specification - Units - Ferrite Number FN ; Ferrite percentage F% - Range - 0 - 115 FN; 0 - 80.5% (percent ferrite) - Resolution - 0.1 FN ; 0.1 F% - Standard: Accuracy (10C - 30C) FN 0 - 10 -- 0.5 FN FN 10 - 30 -- 5% of the reading FN 30 - 100 -- 10% of the reading - Air cooled: Accuracy (30C - 300C) FN 0 - 10 -- 1 FN FN 10 - 30 -- 10% of the reading FN 30 - 100 -- 20% of the reading - Calibration - Factory calibration to NIST standards ; User calibration to supplied transfer standards - Transfer standards - Five transfer standards - Range - typically 3 FN to 115 FN - Zero - Automatic on demand - Mode - Average or peak - Storage - 52 records - PC Download - Optional RS232 and USB - Probe - Pencil style, 15mm diameter length 120mm; Sensing area 10mm diameter - Operating temperature - Standard 0C - 40C; Air cooled 0C - 300C ; Air cooled operation - Air line supply regulated to 1 bar maximum; Oil filtered supply desirable; Air temperature: ambient (10C - 30C) - Humidity - Non-condensing - Weight in case - 1.25 kg - Case dimensions - 210 x 100 x 45 mm

© 2019 Ewelding MarketPlace -TOKO LAS ONLINE. All rights reserved | Design by JAKARTA